Solar Air Conditioner
Energor solar air-conditioner uses solar energy and electricity energy as the auxiliary power,which reaches the effect of photoelectric complementation in accordance with principles of fluid dynamics and achieve the purposes of refrigeratio-n, heating,environmental protection and energy saving by combining traditional air-conditioner technology and adopting the combination of the absorption and compression and ecvironmentally-friendly and energy-efficient refrigerants.
The solar air conditioner can save over 30%-60% on the power consumption compared with standard air conditioner of the same size or same cooling capacity. Solar AC units use a storing energy box in the solar collector to help store solar heat energy,so it can operate with efficiency at night or on cloudy days.

Product Description
Solar Air Conditioner ( Split type )
Reinforced refrigeration
Thin and slim design
Warm startup(cold air prevention)
Independent dehumidification
Ultra-quiet design
Elegant design
Conductor blowing design
| Name: |
Solar Air Conditioner (Split Type) |
| Item No.: |
TKF-35GW Series
|
| Function |
Cooling |
Heating |
Cooling |
Heating |
| Capacity (W) |
3500 |
3600 |
3500 |
3600 |
| Auxiliary Electric Heating Power Consumption(W) |
600 |
| Air Circulation (M3/H) |
540 |
550 |
| Humidifying Power(KG/H) |
1.2 |
1.33 |
| Noise (DBA) |
46(Indoor) , 50(Outdoor) |
| Dimension(D*W*H,mm) |
900X295X370 (Indoor) , 600X750X330 (Outdoor) , 850X90X590 (Solar collector) |
| Net Weight (kg) |
10 (Indoor) , 28 (Outdoor) , 10 (Solar collector) |
| Power Supply |
220V-230V/50HZ |
220V-230V/50HZ 220V-230V/60HZ (with T1 R22) |
| Climate Type |
T1 |
T1 T3 (with 220V-230V/50HZR22) |
| Refrigerant |
R22 |
R22, R410A |
| Load Capacity (20‘) |
114 pcs |
| Load Capacity (40’) |
228 pcs |
Electricity Consume of Solar AC VS Normal AC |
| Hour |
Electricity Consume of Normal AC |
Electricity Consume of Solar AC |
Electricity Saved |
| 1 hour |
1.3 kw |
0.7 kw |
0.6 kw |
| 10 hours |
13 kw |
7 kw |
6 kw |
1 month
(10 hours as 1 day) |
390 kw |
210 kw |
180 kw |
2 months
(10 hours as 1 day) |
780 kw |
420 kw |
360 kw |
5 months
(10 hours as 1 day) |
1950 kw |
1050 kw |
900 kw |
2 years
(5 months as 1 year) |
3900 kw |
2100 kw |
1800 kw |
5 years
(5 months as 1 year) |
9750 kw |
5250 kw |
4500 kw |
-----------------------------------------------------------------------------------------------------------------

Product Description
Solar Air Conditioner ( Floor type )
Reinforced refrigeration
Thin and slim design
Warm startup(cold air prevention)
Independent dehumidification
Ultra-quiet design
Elegant design
Conductor blowing design
| Name: |
Solar Air Conditioner (Floor Type) |
| Item No.: |
TKF(Rd)72LW Series
|
| Function |
Cooling |
Heating
|
| Capacity (W) |
7200 |
7200
|
| Auxiliary Electric Heating Power Consumption(W) |
2000 |
| Air Circulation (M3/H) |
1200
|
| Humidifying Power(KG/H) |
2.3
|
| Noise (DBA) |
52(Indoor) , 56(Outdoor) |
| Dimension(D*W*H,mm) |
1800X350X600 (Indoor) , 930X400X760 (Outdoor), 850X90X590 (Solar collector) |
| Net Weight (kg) |
45 (Indoor), 54 (Outdoor), 10 (Solar collector) |
| Power Supply |
220V-230V/50HZ |
220V-230V/50HZ 220V-230V/60HZ (with T1 R22) |
| Climate Type |
T1 |
T1 T3 (with 220V-230V/50HZR22) |
| Refrigerant |
R22 |
R22, R410A |
| Load Capacity (20‘) |
80 pcs |
| Load Capacity (40’) |
160 pcs |
Electricity Consume of Solar AC VS Normal AC |
| Hour |
Electricity Consume of Normal AC |
Electricity Consume of Solar AC |
Electricity Saved |
| 1 hour |
3.5 kw |
1.7 kw |
1.8 kw |
| 10 hours |
35 kw |
17 kw |
18 kw |
1 month
(10 hours as 1 day) |
1050 kw |
510 kw |
540 kw |
2 months
(10 hours as 1 day) |
2100 kw |
1020 kw |
1080 kw |
5 months
(10 hours as 1 day) |
5250 kw |
2550 kw |
2700 kw |
2 years
(5 months as 1 year) |
10500 kw |
5100 kw |
5400 kw |
5 years
(5 months as 1 year) |
26250 kw |
12750 kw |
13500 kw |
Hang Ceiling,Window,Ceiling& Floor Mounting Type are available, for more details, please contact our sales team, we are pleased to assist you with our best efforts.
Compare with conventional air conditioners:
* Current available technologies are neither practical nor cost-effective.
* Photovoltaic (PV) systems cost is many times more than a conventional air conditioner.
* Thermally driven absorption cooling requires costly, high-temperature collectors and undesirable cooling towers.
Advantage:
*Energor Solar Air-Conditioner quite fits the seasonal demand, which means,the COP is increased as the solar energy is most plentiful in the summer.
* Freon, widely used by conventional air-conditioners, is damaging our atmosphere. Our Solar Air-Conditioner works with our special medium and newest refrigerant which is completely environment friendly.
* Vacuum tube solar collectors were invented in the USA in thirty years ago and then Chinese professor to meliorated it in twenty years ago, this kinds of tube’s efficiency can reach more than 94.35%, mature technology and high quality will guarantee the performance of our Solar Air-Conditioner.
* Energor Solar Air-Conditioner is cost-effective. Our Solar Air-Conditioner system was invented and produced in China, due to the low cost of the labor, land and R&D. The price of our Solar Air-Conditioner system is very competitive and affordable for our clients worldwide.
* Energor Solar Air-Conditioners can combine air-conditioning and solar hot water systems together, therefore enhance market attractiveness.
* Our products have all the functions as conventional Air-Conditioners do.Such as dehumidification and bacteria free ventilation to help refresh the air inside your home or business.
* Our standard products have different capacities which is more easy to design larger systems, that help fit the needs of any commercial project and make our system more customized.
* Easy installation, making operation time less consuming. Our system is compatible with conventional shafts, local conventional certified Air Conditioner installers can get installations done perfectly with 3 days training.
* Our products use high quality components, like HITACHI compressor, all copper tubing and treated stainless steal metal, providing top of the line quality.
Automatic open and close dustproof air outlet
Easy installation, just the same as the traditional air conditioner.With strong adaptability, Energor solar air-conditioner can run at super high and low temperature, exceeding the national standards and applying to all kinds of environment.
Running principle of the solar air-conditioner
Energor solar air-conditioner uses solar energy and electricity energy as the auxiliary power,which reaches the effect of photoelectric complementation in accordance with principles of fluid dynamics and achieve the purposes of refrigeration, heating,environmental protection and energy saving by combining traditional air-conditioner technology and adopting the combination of the absorption and compression and ecvironmentally-friendly and energy-efficient refrigerants.
Abstract:
Solar Air-Conditioner absorb solar energy to heat the inside medium by using vacuum solar collector. The refrigerant from the compressor goes through the copper coil inside the collector and undertake a heat exchange. The refrigerant heated by the medium inside the solar collector will go cycle inside the system cooling and heating. We use a smaller compressor instead of standard compressor to run the system which saving the electricity dramatically. A smaller compressor consumes much less electricity and works together with the solar collector to saving the electricity.